Your current location: Home > Product > Transformer cabinet >
35kV Transformer Cabinet
The switchgear for 40.5kV transformers is a complex electrical equipment that integrates high voltage, high current breaking capacity, reliable five-protection interlocking, precise measurement and protection, and flexible operation and maintenance. Its core parameters (voltage, current, breaking capacity, tolerance, insulation level) determine its basic application range, while its characteristics (removable structure, five-protection interlocking, perfect protection measurement, safety design) ensure its safe, reliable and flexible operation in the power system, providing the necessary control, protection and isolation functions for the transformer. When selecting, the appropriate cabinet type and parameter configuration must be determined based on the specific parameters of the transformer (capacity, impedance voltage), the short-circuit current level of the system, the installation environment conditions, and the operation and maintenance requirements.
  • System voltage:

    40.5kV
  • Rated working voltage:

    35kV
  • Rated current:

    630A, 1250A, 1600A, 2000A, 2500A, 3150A, 4000A
  • Rated frequency:

    50Hz/60Hz Insulation level:.
  • Casing:

    Usually requires IP4X (prevents solid objects with a diameter greater than 1mm from entering), and IP2X is required inside after the door is opened (prevents fingers from touching live parts).
  • Reliable grounding:

    All metal casings, partitions, doors, etc. are reliably grounded.
  • Observation window:

    Used to observe the status of internal components.
Consult immediately

Core parameters

Core features and advantages

Download

System and rated voltage
The system voltage is 40.5kV, and the rated working voltage is 35kV. The system voltage is the highest voltage of the equipment in the power grid, and the rated voltage is the standard voltage for the normal operation of the equipment. The two determine the voltage adaptation range of the switchgear in the power grid to ensure its stable operation under the specified voltage.


Rated current range
The rated current has multiple specifications from 630A to 4000A. Different rated currents meet the needs of transformers of different capacities and loads. The larger the current, the higher the conductivity and heat dissipation design requirements of the switchgear to ensure safe and reliable transmission of electric energy under large currents.


Rated frequency
The rated frequency is 50Hz/60Hz. The frequency affects the electromagnetic design and operating characteristics of the equipment. The power grid frequencies in different regions are different. The switchgear needs to adapt to the local power grid frequency to ensure that it works in coordination with the transformer and other equipment to ensure the stable operation of the power system.

Removable structure
The removable structure facilitates the installation, maintenance and replacement of equipment. The removable parts of the switch cabinet (such as the circuit breaker trolley) can be flexibly moved out or pushed in, reducing the scope of power outage during equipment maintenance, improving the availability and maintenance efficiency of the equipment, and adapting to the power system's requirements for equipment reliability and flexibility.


Five-protection interlocking
The five-protection interlocking ensures the safety of equipment operation. Preventing the wrong opening and closing of circuit breakers, pulling and closing disconnectors with load, hanging ground wires with power, closing circuit breakers with ground wires, and mistakenly entering live intervals, etc., is achieved through mechanical or electrical interlocking devices, avoiding accidents caused by misoperation and ensuring the safe and stable operation of the power system.


Accurate measurement protection
The integrated accurate measurement protection function can monitor parameters such as voltage, current, and power in real time, and perform protection actions according to the set values. Such as overcurrent protection, quick-break protection, grounding protection, etc., can quickly detect faults and cut off faulty circuits, protect transformers and switch cabinets from damage, and improve the reliability and service life of equipment.


Flexible operation and maintenance
The operation and maintenance are flexible and convenient, with complete indication and operation mechanisms. The operator can operate the switch cabinet by local or remote control. At the same time, the equipment is equipped with clear indicator lights and status displays, which makes it easy for the operator to understand the operating status of the equipment and facilitate daily operation and maintenance work.

Copyright © Jiangsu Simao Electrical Engineering Co., Ltd. All rights reserved